SEIKO PT8000X |
Top Previous Next |
Select the 'SEIKO PT8000X' Click on Set-up from the Main Menu Bar and then Timing Console INTERFACE. Now click on the Seiko radio button and then OK. Now click on Run from the Main Menu Bar, click Timer, click Open Serial/Close Port, and choose the COM port that your PT8000X is connected to on your computer and then click OK.
Reading in Results From the 'SEIKO PT8000X' Choose the Event and the Heat, ensure the The reaction time or split time, and goal time sent from the PT8000X, click the 'Get Times' to get the related result. The running time is not displayed, and the operator performs the operation to obtain the results every time the race ends. It will not be displayed on the screen unless you perform the result acquisition operation (it is not displayed automatically).
Please Note •There is no identifying marking for backup time. oThe PT8000X sends one detected split or goal time via grip switch when the touch pad cannot detect the time. This time serves as a backup time. However, Hy-Tek Swim MM does not have a function to add such an identifying mark to backup time. •There is no detection of relay taking-over time. oThe PT8000X detects the time the 2nd swimmer leaves the starting block after the 1st swimmer pushes the touch pad. The time between the 2nd swimmer and the 3rd swimmer is the same. We refer to this as relay taking-over time. However, Hy-Tek Swim MM does not have a function to detect this taking-over time. •DNF information is input through the Hy-Tek Swim MM run screen.
|